BASIC WIRING PRACTICE - Practice Mode
1) What is the function of circuit breaker?
Correct Answer: Breaking automatically at abnormal condition
3) What protection offered by residual current circuit breaker?
Correct Answer: Protection from shock
4) Which wiring is suitable for temporary installations?
Correct Answer: Cleat wiring
Explanation:
Cleat wiring comprises of PVC insulated wires or ordinary VIR that are braided and compounded. They are held on walls and ceilings using porcelain cleats with groves, wood or plastic. Cleat wiring is a temporary wiring system, therefore making it unsuitable for domestic premises.
5) Where the phase conductor is looped in looping system of wiring?
Correct Answer: Socket connection